• facebook
  • linkedin
  • twitter
  • google
  • youtube

S100A-AA-W(433/868) – Interconnected Battery Smoke Alarms

Short Description:

The RF Interconnected Battery Smoke Detector features an infrared photoelectric sensor, reliable MCU, and SMT technology for high sensitivity, stability, and low power consumption. With its wireless interconnection and long-lasting battery, it’s ideal for smoke detection in homes, factories, stores, warehouses, and more.


  • What we provide?: Wholesale price,OEM ODM service,Product training ect.
  • Product Detail

    Product Tags

    Product Introduction

    The RF Interconnected Battery Smoke Detector uses a photoelectric sensor with a specially designed structure and a reliable MCU to effectively detect smoke during the initial smoldering stage or after a fire. When smoke enters the alarm, the light source scatters light, and the receiving element detects the light intensity (which has a linear relationship with smoke concentration). The alarm continuously collects, analyzes, and evaluates field data. Once the light intensity reaches the predetermined threshold, the red LED light illuminates, and the buzzer sounds an alarm. The alarm automatically resets to normal operation when smoke dissipates. The wireless interconnection feature ensures that alarms can communicate with other units, providing enhanced safety coverage. Powered by a long-lasting battery, it is suitable for homes, offices, factories, and other environments.

    Parameter Details
    Model S100A-AA-W(RF 433/868)
    Decibel >85dB (3m)
    Working voltage DC3V
    Static current <25μA
    Alarm current <150mA
    Low battery voltage 2.6V ± 0.1V
    Operation temperature -10°C to 50°C
    Relative Humidity <95%RH (40°C ± 2°C, Non-condensing)
    Indicator light failure impact The failure of the two indicator lights does not affect the normal use of the alarm
    Alarm LED light Red
    RF Wireless LED light Green
    Output form Audible and Visual alarm
    RF mode FSK
    RF frequency 433.92MHz / 868.4MHz
    Silent time About 15 minutes
    RF Distance (Open sky) Open sky <100 meters
    RF Distance (Indoor) <50 meters (according to the environment)
    Battery Capacity 2pcs AA battery;Each one is 2900mah
    Battery life About 3 years (may vary depending on usage environment)
    RF wireless devices support Up to 30 pieces
    Net weight (N.W.) About 157g (contains batteries)
    Standard EN 14604:2005, EN 14604:2005/AC:2008

    RF Create a group in the first use (i.e. 1/2)

    Take any two alarms that need to be set up as groups and number them as " 1"
    and "2" respectively.
    1. Devices must work with the same frequency. 2. The distance between the two devices is about 30-50CM.
    3.Before pairing the smoke detector, please insert 2 AA batteries correctly.
    After hearing the sound and seeing the light, wait 30 seconds before performing the
    following operations.
    4. Press the "RESET button" three times, the green LED lights up means it is in
    networking mode.
    5. Press the “RESET button” of 1 or 2 again, you will hear three “DI” sounds, which means the connection starts.
    6. The green LED of 1 and 2 flashing three times slowly, which means that the
    connection is successful.
    [Notes and Notices]
    1. RESET button. (Figure 1)
    2. Green light.
    3. Complete the connection within one minute. If exceeds one minute, the product identifies as timeout, you need to re-connect.
    RESET button of interconnected smoke detector

    How to Added more alarms to Group (3 - N)

    1. Take the 3 (or N) alarm.
    2. Press the "RESET button" three times.
    3. Select any alarm (1 or 2) that has been set up in a group, press the
    "RESET button" of 1 and wait for the connection after three "DI" sounds.
    4. The new alarms’green led flashing three times slowly, the device is successfully
    connected to 1.
    5. Repeat the above steps to add more devices.
    [Notes and Notices]
    1. If there are many alarms to be added, please add them in batches( 8-9 pcs in one
    batch),otherwise, network failure due to the time exceeding one minute.
    2. Maximum 30 devices in a group.
    Exit the group
    Press the "RESET button" twice quickly, after the green LED flashes twice, press and
    hold the "RESET button" until the green light flashes quickly, meaning it has
    successfully exited the group.

    Installation and Test

    For general places, when the space height is less than 6m, the alarm with a protection
    area of 60m. The alarm shall be mounted on the ceiling.
    1. Remove the ceiling mount.

     

    Rotate the alarm anticlockwise out of the ceiling mount
    2. Drill two holes with a spacing of 80mm on the ceiling with a suitable drill, and then
    stick the included anchors in the holes and mount the ceiling install with both screws.
    how to install on the Celling
    3. Install 2pcs AA batteries in the correct direction.
    Note: If the positive and negative polarity of the battery is reversed, the alarm cannot
    work normally and may damage the alarm.
    4. Press the TEST / HUSH button, all paired smoke detectors will alarm and LED flash.
    If not: Please check if the battery is installed correctly, the battery voltage is too low
    (less than 2.6V ±0.1V) or smoke detectors not paired successfully.
    5. After testing, simply screw the detector in the ceiling mount until you hear a "click".
    more step for installation
    1.How do this smoke alarms work?

    They detect smoke in one location and trigger all connected alarms to sound simultaneously, enhancing safety.

    2.Can the alarms connect wirelessly without a hub?

    Yes, the alarms use RF technology to connect wirelessly without requiring a central hub.

    3.What happens when one alarm detects smoke?

    When one alarm detects smoke, all interconnected alarms in the network will activate together.

    4.How far can the alarms communicate with each other?

    They can communicate wirelessly up to 65.62ft(20 meters) in open spaces and 50 meters indoors.

    5.Are these alarms battery-powered or hardwired?

    They are battery-powered, making installation simple and flexible for various environments.

    6.How long does the battery last in these alarms?

    The batteries have an average lifespan of 3 years under normal usage conditions.

    7.Are these alarms compliant with safety standards?

    Yes, they meet EN 14604:2005 and EN 14604:2005/AC:2008 safety certification requirements.

    8.What is the decibel level of the alarm sound?

    The alarm emits a sound level of over 85dB, loud enough to alert occupants effectively.

    9.How many alarms can be interconnected in one system?

    A single system supports interconnection of up to 30 alarms for extended coverage.